    Torsional Vibration Measurement and Analysis on Flue Gas Blower
    PS
    • Jun 24
    • 1 min

    Torsional Vibration Measurement and Analysis on Flue Gas Blower

    Recently, we did torsional vibration measurement on a disk-pack coupling of 315 kW induction motor driven flue gas blower. A strain gauge...
    3 views0 comments
    Oil whip instability vibration in generator
    RC
    • Feb 9
    • 4 min

    Oil whip instability vibration in generator

    A steam turbine-generator set was overhauled for about two (2) months before it was attempted to put back to services again. However,...
    205 views0 comments
    Commissioning support and troubleshooting high vibration problem on a new steam turbine
    RC
    • Jan 13
    • 2 min

    Commissioning support and troubleshooting high vibration problem on a new steam turbine

    This is our last job of year 2021 working on a new steam turbine – generator set during commissioning. Unit installation was completed...
    57 views0 comments
    Vibration analysis on hydroturbine-generator set with high-speed camera
    RC
    • Dec 7, 2021
    • 2 min

    Vibration analysis on hydroturbine-generator set with high-speed camera

    This is a case study of using motion amplification® (MA) technology to analyze vibration data of a small hydroturbine-generator set...
    40 views0 comments
    Motion amplification of cooling water pipe
    RC
    • Oct 22, 2021
    • 2 min

    Motion amplification of cooling water pipe

    Crack is noticed at cooling water pipe of a large generator which is suspected due to excessive vibration. Motion amplification (MA) is...
    44 views0 comments
    Air duct vibration analysis with motion amplification and fatigue assessment
    RC
    • Sep 20, 2021
    • 1 min

    Air duct vibration analysis with motion amplification and fatigue assessment

    This is a case study of vibration measurement and analysis on air duct of primary air fan installed at a new thermal power plant....
    76 views0 comments
    Bump Test with Motion Amplification Camera
    PS
    • Oct 28, 2019
    • 2 min

    Bump Test with Motion Amplification Camera

    In general we perform bump/impact test to find natural frequency as rough test to prove if resonance problem exists. But however if we...
    285 views0 comments
    The impossible is now possible : measuring pipe vibration inside the furnace
    RC
    • Nov 26, 2018
    • 1 min

    The impossible is now possible : measuring pipe vibration inside the furnace

    High vibration was observed at pipes installed inside the furnace in a refinery and this results in a concern of fatigue failure. This...
    131 views0 comments
    Out of reach, yes we can!
    RC
    • Jul 25, 2018
    • 1 min

    Out of reach, yes we can!

    One of the reasons we invested in Iris M Motion Amplification (MA) camera is for piping including its associated structures and...
    90 views0 comments
    Motion amplification of agitator
    RC
    • Jun 2, 2018
    • 2 min

    Motion amplification of agitator

    An agitator installed in petrochemical plant is reported excessive vibration amplitudes measured at motor, gearbox and associated...
    317 views0 comments
    Introduction to Piping Vibration Analysis
    RC
    • Feb 18, 2018
    • 3 min

    Introduction to Piping Vibration Analysis

    From our experience piping vibration problem is increasing demand for analysis and field troubleshooting which can be due to increasing...
    1,183 views0 comments
    Big Loss Field Balancing
    PS
    • Jan 29, 2018
    • 2 min

    Big Loss Field Balancing

    We were requested to witness field balancing on a primary air fan being performed by third party. They were using handheld vibration data...
    111 views0 comments
    Solving resonance problem of cooling oil pipe
    RC
    • Jan 26, 2018
    • 1 min

    Solving resonance problem of cooling oil pipe

    Cooling oil pipe of 700 MW transformer revealed excessive vibration amplitude measured at cooling oil pump at more than 200 microns, pp...
    137 views0 comments